{"$ref":"https://www.cert.ssi.gouv.fr/openapi.json","affected_systems":[{"description":"Modicon Premium","product":{"name":"N/A","vendor":{"name":"Schneider Electric","scada":true}}},{"description":"Modicon M340","product":{"name":"Modicon M340","vendor":{"name":"Schneider Electric","scada":true}}},{"description":"EcoStruxure Power Monitoring Expert versions ant\u00e9rieures \u00e0 PME 9.0 CU2","product":{"name":"N/A","vendor":{"name":"Schneider Electric","scada":true}}},{"description":"Modicon BMxCRA et les modules 140CRA","product":{"name":"N/A","vendor":{"name":"Schneider Electric","scada":true}}},{"description":"Modicon BMENOC 0321","product":{"name":"N/A","vendor":{"name":"Schneider Electric","scada":true}}},{"description":"Modicon BMENOC 0311","product":{"name":"N/A","vendor":{"name":"Schneider Electric","scada":true}}},{"description":"Modicon M580","product":{"name":"N/A","vendor":{"name":"Schneider Electric","scada":true}}},{"description":"SoMove FDT versions v2.7.5 et ant\u00e9rieures","product":{"name":"N/A","vendor":{"name":"Schneider Electric","scada":true}}},{"description":"EcoStruxure Power Monitoring Expert version 8.2 sans le dernier correctif de s\u00e9curit\u00e9","product":{"name":"N/A","vendor":{"name":"Schneider Electric","scada":true}}},{"description":"Modicon Quantum","product":{"name":"N/A","vendor":{"name":"Schneider Electric","scada":true}}}],"affected_systems_content":null,"content":"## Solution\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l'\u00e9diteur pour l'obtention des\ncorrectifs (cf. section Documentation).\n","cves":[{"name":"CVE-2018-7833","url":"https://www.cve.org/CVERecord?id=CVE-2018-7833"},{"name":"CVE-2019-6846","url":"https://www.cve.org/CVERecord?id=CVE-2019-6846"},{"name":"CVE-2018-7830","url":"https://www.cve.org/CVERecord?id=CVE-2018-7830"},{"name":"CVE-2018-7809","url":"https://www.cve.org/CVERecord?id=CVE-2018-7809"},{"name":"CVE-2019-6841","url":"https://www.cve.org/CVERecord?id=CVE-2019-6841"},{"name":"CVE-2019-6848","url":"https://www.cve.org/CVERecord?id=CVE-2019-6848"},{"name":"CVE-2018-7810","url":"https://www.cve.org/CVERecord?id=CVE-2018-7810"},{"name":"CVE-2018-7831","url":"https://www.cve.org/CVERecord?id=CVE-2018-7831"},{"name":"CVE-2018-20031","url":"https://www.cve.org/CVERecord?id=CVE-2018-20031"},{"name":"CVE-2019-6845","url":"https://www.cve.org/CVERecord?id=CVE-2019-6845"},{"name":"CVE-2018-20032","url":"https://www.cve.org/CVERecord?id=CVE-2018-20032"},{"name":"CVE-2019-6844","url":"https://www.cve.org/CVERecord?id=CVE-2019-6844"},{"name":"CVE-2019-6842","url":"https://www.cve.org/CVERecord?id=CVE-2019-6842"},{"name":"CVE-2018-20034","url":"https://www.cve.org/CVERecord?id=CVE-2018-20034"},{"name":"CVE-2019-6851","url":"https://www.cve.org/CVERecord?id=CVE-2019-6851"},{"name":"CVE-2018-20033","url":"https://www.cve.org/CVERecord?id=CVE-2018-20033"},{"name":"CVE-2019-6826","url":"https://www.cve.org/CVERecord?id=CVE-2019-6826"},{"name":"CVE-2018-7811","url":"https://www.cve.org/CVERecord?id=CVE-2018-7811"},{"name":"CVE-2019-6849","url":"https://www.cve.org/CVERecord?id=CVE-2019-6849"},{"name":"CVE-2019-6847","url":"https://www.cve.org/CVERecord?id=CVE-2019-6847"},{"name":"CVE-2018-7804","url":"https://www.cve.org/CVERecord?id=CVE-2018-7804"},{"name":"CVE-2019-6843","url":"https://www.cve.org/CVERecord?id=CVE-2019-6843"},{"name":"CVE-2019-6850","url":"https://www.cve.org/CVERecord?id=CVE-2019-6850"},{"name":"CVE-2018-7812","url":"https://www.cve.org/CVERecord?id=CVE-2018-7812"}],"links":[],"reference":"CERTFR-2019-AVI-488","revisions":[{"description":"Version initiale","revision_date":"2019-10-08T00:00:00.000000"}],"risks":[{"description":"D\u00e9ni de service \u00e0 distance"},{"description":"Injection de code indirecte \u00e0 distance (XSS)"},{"description":"Ex\u00e9cution de code arbitraire \u00e0 distance"},{"description":"Contournement de la politique de s\u00e9curit\u00e9"},{"description":"Atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es"}],"summary":"De multiples vuln\u00e9rabilit\u00e9s ont \u00e9t\u00e9 d\u00e9couvertes dans les produits\nSchneider Electric. Certaines d'entre elles permettent \u00e0 un attaquant de\nprovoquer une ex\u00e9cution de code arbitraire \u00e0 distance, un d\u00e9ni de\nservice \u00e0 distance et un contournement de la politique de s\u00e9curit\u00e9.\n","title":"Multiples vuln\u00e9rabilit\u00e9s dans les produits Schneider Electric","vendor_advisories":[{"published_at":null,"title":"Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2019-281-02 du 08 octobre 2019","url":"https://download.schneider-electric.com/files?p_enDocType=Technical+leaflet&p_File_Name=SEVD-2019-281-02_Modicon_Controllers.pdf&p_Doc_Ref=SEVD-2019-281-02"},{"published_at":null,"title":"Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2019-134-04 du 08 octobre 2019","url":"https://download.schneider-electric.com/files?p_enDocType=Technical+leaflet&p_File_Name=SEVD-2019-134-04-Floating-License-Manager-Update_V2.1.pdf&p_Doc_Ref=SEVD-2019-134-04"},{"published_at":null,"title":"Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2018-327-01 du 08 octobre 2019","url":"https://download.schneider-electric.com/files?p_enDocType=Technical+leaflet&p_File_Name=SEVD-2018-327-01-Embedded-Web-Servers-Modicon+V3.0.pdf&p_Doc_Ref=SEVD-2018-327-01"},{"published_at":null,"title":"Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2019-281-04 du 08 octobre 2019","url":"https://download.schneider-electric.com/files?p_enDocType=Technical+leaflet&p_File_Name=SEVD-2019-281-04_Modicon_Controllers.pdf&p_Doc_Ref=SEVD-2019-281-04"},{"published_at":null,"title":"Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2019-281-01 du 08 octobre 2019","url":"https://download.schneider-electric.com/files?p_enDocType=Technical+leaflet&p_File_Name=SEVD-2019-281-01_Modicon_Controllers.pdf&p_Doc_Ref=SEVD-2019-281-01"},{"published_at":null,"title":"Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2019-225-04 du 08 octobre 2019","url":"https://download.schneider-electric.com/files?p_enDocType=Technical+leaflet&p_File_Name=SEVD-2019-225-04_SoMachine_SoMove_V2.0.pdf&p_Doc_Ref=SEVD-2019-225-04"},{"published_at":null,"title":"Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2019-281-03 du 08 octobre 2019","url":"https://download.schneider-electric.com/files?p_enDocType=Technical+leaflet&p_File_Name=SEVD-2019-281-03_Modicon_Controllers.pdf&p_Doc_Ref=SEVD-2019-281-03"}]}