{"$ref":"https://www.cert.ssi.gouv.fr/openapi.json","affected_systems":[{"description":"SIMATIC S7-400 CPU 414F-3 PN/DP V7 (6ES7414-3FM07-0AB0) versions ant\u00e9rieures \u00e0 V7.0.3","product":{"name":"N/A","vendor":{"name":"Siemens","scada":true}}},{"description":"Siveillance Video 2022 R1 versions ant\u00e9rieures \u00e0 V22.1 HotfixRev7","product":{"name":"N/A","vendor":{"name":"Siemens","scada":true}}},{"description":"Siveillance Video 2021 R1 versions ant\u00e9rieures \u00e0 V21.1 HotfixRev12","product":{"name":"N/A","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE LPE9403 (6GK5998-3GS00-2AC2) versions ant\u00e9rieures \u00e0 V2.1","product":{"name":"N/A","vendor":{"name":"Siemens","scada":true}}},{"description":"Siveillance Video 2022 R2 versions ant\u00e9rieures \u00e0 V22.2 HotfixRev5","product":{"name":"N/A","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE W1750D (ROW) (6GK5750-2HX01-1AA0) toutes versions","product":{"name":"N/A","vendor":{"name":"Siemens","scada":true}}},{"description":"SIMATIC S7-400 CPU 416F-3 PN/DP V7 (6ES7416-3FS07-0AB0) versions ant\u00e9rieures \u00e0 V7.0.3","product":{"name":"N/A","vendor":{"name":"Siemens","scada":true}}},{"description":"SIMATIC S7-400 CPU 412-2 PN V7 (6ES7412-2EK07-0AB0) versions ant\u00e9rieures \u00e0 V7.0.3","product":{"name":"N/A","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE W1750D (JP) (6GK5750-2HX01-1AD0) toutes versions","product":{"name":"N/A","vendor":{"name":"Siemens","scada":true}}},{"description":"Siveillance Video 2020 R3 versions ant\u00e9rieures \u00e0 V20.3 HotfixRev12","product":{"name":"N/A","vendor":{"name":"Siemens","scada":true}}},{"description":"Siveillance Video 2022 R3 versions ant\u00e9rieures \u00e0 V22.3 HotfixRev2","product":{"name":"N/A","vendor":{"name":"Siemens","scada":true}}},{"description":"Siveillance Video 2023 R1 versions ant\u00e9rieures \u00e0 V23.1 HotfixRev1","product":{"name":"N/A","vendor":{"name":"Siemens","scada":true}}},{"description":"Siveillance Video 2020 R2 versions ant\u00e9rieures \u00e0 V20.2 HotfixRev14","product":{"name":"N/A","vendor":{"name":"Siemens","scada":true}}},{"description":"Siveillance Video 2021 R2 versions ant\u00e9rieures \u00e0 V21.2 HotfixRev8","product":{"name":"N/A","vendor":{"name":"Siemens","scada":true}}},{"description":"SIMATIC Cloud Connect 7 CC716 (6GK1411-5AC00) versions V2.x versions ant\u00e9rieures \u00e0 V2.1","product":{"name":"N/A","vendor":{"name":"Siemens","scada":true}}},{"description":"SIMATIC Cloud Connect 7 CC712 (6GK1411-1AC00) versions V2.x versions ant\u00e9rieures \u00e0 V2.1","product":{"name":"N/A","vendor":{"name":"Siemens","scada":true}}},{"description":"SINEC NMS versions ant\u00e9rieures \u00e0 V1.0.3.1","product":{"name":"N/A","vendor":{"name":"Siemens","scada":true}}},{"description":"SIMATIC S7-400 CPU 414-3 PN/DP V7 (6ES7414-3EM07-0AB0) versions ant\u00e9rieures \u00e0 V7.0.3","product":{"name":"N/A","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE W1750D (USA) (6GK5750-2HX01-1AB0) toutes versions","product":{"name":"N/A","vendor":{"name":"Siemens","scada":true}}},{"description":"SIMATIC S7-400 CPU 416-3 PN/DP V7 (6ES7416-3ES07-0AB0) versions ant\u00e9rieures \u00e0 V7.0.3","product":{"name":"N/A","vendor":{"name":"Siemens","scada":true}}},{"description":"Solid Edge SE2023 versions ant\u00e9rieures \u00e0 VX.223.0 Update 3","product":{"name":"N/A","vendor":{"name":"Siemens","scada":true}}}],"affected_systems_content":null,"content":"## Solution\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l'\u00e9diteur pour l'obtention des\ncorrectifs (cf. section Documentation).\n","cves":[{"name":"CVE-2022-35252","url":"https://www.cve.org/CVERecord?id=CVE-2022-35252"},{"name":"CVE-2022-35260","url":"https://www.cve.org/CVERecord?id=CVE-2022-35260"},{"name":"CVE-2023-28832","url":"https://www.cve.org/CVERecord?id=CVE-2023-28832"},{"name":"CVE-2023-0973","url":"https://www.cve.org/CVERecord?id=CVE-2023-0973"},{"name":"CVE-2023-29105","url":"https://www.cve.org/CVERecord?id=CVE-2023-29105"},{"name":"CVE-2023-29128","url":"https://www.cve.org/CVERecord?id=CVE-2023-29128"},{"name":"CVE-2022-42916","url":"https://www.cve.org/CVERecord?id=CVE-2022-42916"},{"name":"CVE-2023-27407","url":"https://www.cve.org/CVERecord?id=CVE-2023-27407"},{"name":"CVE-2023-29104","url":"https://www.cve.org/CVERecord?id=CVE-2023-29104"},{"name":"CVE-2023-27409","url":"https://www.cve.org/CVERecord?id=CVE-2023-27409"},{"name":"CVE-2022-43552","url":"https://www.cve.org/CVERecord?id=CVE-2022-43552"},{"name":"CVE-2019-10936","url":"https://www.cve.org/CVERecord?id=CVE-2019-10936"},{"name":"CVE-2023-30985","url":"https://www.cve.org/CVERecord?id=CVE-2023-30985"},{"name":"CVE-2023-30899","url":"https://www.cve.org/CVERecord?id=CVE-2023-30899"},{"name":"CVE-2023-29107","url":"https://www.cve.org/CVERecord?id=CVE-2023-29107"},{"name":"CVE-2022-42915","url":"https://www.cve.org/CVERecord?id=CVE-2022-42915"},{"name":"CVE-2022-32221","url":"https://www.cve.org/CVERecord?id=CVE-2022-32221"},{"name":"CVE-2022-40674","url":"https://www.cve.org/CVERecord?id=CVE-2022-40674"},{"name":"CVE-2022-43551","url":"https://www.cve.org/CVERecord?id=CVE-2022-43551"},{"name":"CVE-2022-47522","url":"https://www.cve.org/CVERecord?id=CVE-2022-47522"},{"name":"CVE-2022-43680","url":"https://www.cve.org/CVERecord?id=CVE-2022-43680"},{"name":"CVE-2023-27410","url":"https://www.cve.org/CVERecord?id=CVE-2023-27410"},{"name":"CVE-2023-29106","url":"https://www.cve.org/CVERecord?id=CVE-2023-29106"},{"name":"CVE-2023-30986","url":"https://www.cve.org/CVERecord?id=CVE-2023-30986"},{"name":"CVE-2023-30898","url":"https://www.cve.org/CVERecord?id=CVE-2023-30898"},{"name":"CVE-2023-27408","url":"https://www.cve.org/CVERecord?id=CVE-2023-27408"},{"name":"CVE-2023-29103","url":"https://www.cve.org/CVERecord?id=CVE-2023-29103"}],"links":[],"reference":"CERTFR-2023-AVI-0370","revisions":[{"description":"Version initiale","revision_date":"2023-05-10T00:00:00.000000"}],"risks":[{"description":"D\u00e9ni de service \u00e0 distance"},{"description":"Ex\u00e9cution de code arbitraire \u00e0 distance"},{"description":"Atteinte \u00e0 l'int\u00e9grit\u00e9 des donn\u00e9es"},{"description":"Contournement de la politique de s\u00e9curit\u00e9"},{"description":"Atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es"}],"summary":"De multiples vuln\u00e9rabilit\u00e9s ont \u00e9t\u00e9 d\u00e9couvertes dans <span\nclass=\"textit\">les produits Siemens</span>. Elles permettent \u00e0 un\nattaquant de provoquer une ex\u00e9cution de code arbitraire \u00e0 distance, un\nd\u00e9ni de service, une atteinte \u00e0 l'int\u00e9grit\u00e9 des donn\u00e9es, un\ncontournement de la politique de s\u00e9curit\u00e9, une atteinte \u00e0 la\nconfidentialit\u00e9 des donn\u00e9es, un d\u00e9ni de service \u00e0 distance et une\nex\u00e9cution de code arbitraire.\n","title":"Multiples vuln\u00e9rabilit\u00e9s dans les produits Siemens","vendor_advisories":[{"published_at":null,"title":"Bulletin de s\u00e9curit\u00e9 Siemens SSA-789345 du 09 mai 2023","url":"https://cert-portal.siemens.com/productcert/html/ssa-516174.html"},{"published_at":null,"title":"Bulletin de s\u00e9curit\u00e9 Siemens SSA-325383 du 09 mai 2023","url":"https://cert-portal.siemens.com/productcert/html/ssa-789345.html"},{"published_at":null,"title":"Bulletin de s\u00e9curit\u00e9 Siemens SSA-516174 du 09 mai 2023","url":"https://cert-portal.siemens.com/productcert/html/ssa-555292.html"},{"published_at":null,"title":"Bulletin de s\u00e9curit\u00e9 Siemens SSA-932528 du 09 mai 2023","url":"https://cert-portal.siemens.com/productcert/html/ssa-892048.html"},{"published_at":null,"title":"Bulletin de s\u00e9curit\u00e9 Siemens SSA-892048 du 09 mai 2023","url":"https://cert-portal.siemens.com/productcert/html/ssa-325383.html"},{"published_at":null,"title":"Bulletin de s\u00e9curit\u00e9 Siemens SSA-555292 du 09 mai 2023","url":"https://cert-portal.siemens.com/productcert/html/ssa-932528.html"},{"published_at":null,"title":"Bulletin de s\u00e9curit\u00e9 Siemens SSA-473245 du 08 octobre 2019","url":"https://cert-portal.siemens.com/productcert/html/ssa-473245.html"}]}