{"$ref":"https://www.cert.ssi.gouv.fr/openapi.json","affected_systems":[{"description":"SCALANCE X204RNA EEC (PRP) (6GK5204-0BS00-3LA3) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE XR324-4M PoE (230V, ports on front) (6GK5324-4QG00-3AR2) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE XR322-12 (6GK5334-3TS00-3AR3) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE X200-4P IRT (6GK5200-4AH00-2BA3) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE XR324-4M PoE (230V, ports on rear) (6GK5324-4QG10-3HR2) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SIPROTEC 5 7SJ86 (CP200) toutes versions. L'\u00e9diteur indique que le produit ne b\u00e9n\u00e9ficiera pas de correctif de s\u00e9curit\u00e9 pour la vuln\u00e9rabilit\u00e9 CVE-2025-40808.","product":{"name":"SIPROTEC","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE X202-2P IRT PRO (6GK5202-2JR00-2BA6) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE XR324-4M PoE (230V, ports on front) (6GK5324-4QG10-3AR2) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SIMATIC WinCC Runtime Advanced V17 versions ant\u00e9rieures \u00e0 17.0.9","product":{"name":"SIMATIC","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front) (6GK5324-4GG10-3ER2) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear) (6GK5324-4GG10-3JR2) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE MUM853-1 (EU) (6GK5853-2EA00-2DA1) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SIPLUS NET SCALANCE X202-2P IRT (6AG1202-2BH00-2BA3) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SIPLUS","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE M826-2 SHDSL-Router (6GK5826-2AB00-2AB2) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SIMATIC WinCC Unified PC Runtime V18 toutes versions. L'\u00e9diteur indique que le produit ne b\u00e9n\u00e9ficiera pas de correctif de s\u00e9curit\u00e9 pour la vuln\u00e9rabilit\u00e9 CVE-2026-24349.","product":{"name":"SIMATIC","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE X302-7 EEC (24V) (6GK5302-7GD00-1EA3) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SIPROTEC 5 7KE85 (CP300) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-40808","product":{"name":"SIPROTEC","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE X307-3LD (6GK5307-3BM10-2AA3) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE X304-2FE (6GK5304-2BD00-2AA3) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SIMATIC RTLS Locating Manager (6GT2780-1EA30) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SIMATIC","vendor":{"name":"Siemens","scada":true}}},{"description":"SIPROTEC 5 6MD86 (CP200) toutes versions. L'\u00e9diteur indique que le produit ne b\u00e9n\u00e9ficiera pas de correctif de s\u00e9curit\u00e9 pour la vuln\u00e9rabilit\u00e9 CVE-2025-40808.","product":{"name":"SIPROTEC","vendor":{"name":"Siemens","scada":true}}},{"description":"SIPROTEC 5 7UT86 (CP200) toutes versions. L'\u00e9diteur indique que le produit ne b\u00e9n\u00e9ficiera pas de correctif de s\u00e9curit\u00e9 pour la vuln\u00e9rabilit\u00e9 CVE-2025-40808.","product":{"name":"SIPROTEC","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE X302-7 EEC (2x 230V) (6GK5302-7GD00-4EA3) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SIPROTEC 5 6MU85 (CP300) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-40808","product":{"name":"SIPROTEC","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE X204-2FM (6GK5204-2BB11-2AA3) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SIPROTEC 5 7SA82 (CP100) toutes versions. L'\u00e9diteur indique que le produit ne b\u00e9n\u00e9ficiera pas de correctif de s\u00e9curit\u00e9 pour la vuln\u00e9rabilit\u00e9 CVE-2025-40808.","product":{"name":"SIPROTEC","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE WUM763-1 (US) (6GK5763-1AL00-3AB0) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SIPROTEC 5 7SK85 (CP300) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-40808","product":{"name":"SIPROTEC","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE M876-3 (ROK) (6GK5876-3AA02-2EA2) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE MUM856-1 (A1) (6GK5856-2EA10-3AA1) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE X307-3LD (6GK5307-3BM00-2AA3) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE MUM856-1 (RoW) (6GK5856-2EA00-3AA1) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SIMATIC Comfort/Mobile RT toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SIMATIC","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE M804PB (6GK5804-0AP00-2AA2) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SIPROTEC 5 7SJ85 (CP300) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-40808","product":{"name":"SIPROTEC","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE XR324-12M (230V, ports on rear) (6GK5324-0GG00-3HR2) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SIPROTEC 5 7SL87 (CP300) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-40808","product":{"name":"SIPROTEC","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE X310 (6GK5310-0FA00-2AA3) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE XR326-8 (6GK5334-2TS00-4AR3) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE SC646-2C (6GK5646-2GS00-2AC2) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SIMATIC HMI Comfort Panels versions ant\u00e9rieures \u00e0 17.0.9","product":{"name":"SIMATIC","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE X216 (6GK5216-0BA00-2AA3) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE X208 (6GK5208-0BA10-2AA3) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE X206-1LD (6GK5206-1BC10-2AA3) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SIMATIC WinCC Unified PC Runtime V17 toutes versions. L'\u00e9diteur indique que le produit ne b\u00e9n\u00e9ficiera pas de correctif de s\u00e9curit\u00e9 pour la vuln\u00e9rabilit\u00e9 CVE-2026-24349.","product":{"name":"SIMATIC","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE XR526-8 (6GK5534-2TR00-3AR3) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SIPROTEC 5 7SX85 (CP300) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-40808","product":{"name":"SIPROTEC","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE XC424-4 (6GK5428-4TR00-2AC2) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE X308-2LD (6GK5308-2FM10-2AA3) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE X204-2LD (6GK5204-2BC10-2AA3) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SIMATIC MV530 S (6GF3530-0CD10) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SIMATIC","vendor":{"name":"Siemens","scada":true}}},{"description":"SIPROTEC 5 7SJ85 (CP200) toutes versions. L'\u00e9diteur indique que le produit ne b\u00e9n\u00e9ficiera pas de correctif de s\u00e9curit\u00e9 pour la vuln\u00e9rabilit\u00e9 CVE-2025-40808.","product":{"name":"SIPROTEC","vendor":{"name":"Siemens","scada":true}}},{"description":"SIPROTEC 5 7SS85 (CP200) toutes versions. L'\u00e9diteur indique que le produit ne b\u00e9n\u00e9ficiera pas de correctif de s\u00e9curit\u00e9 pour la vuln\u00e9rabilit\u00e9 CVE-2025-40808.","product":{"name":"SIPROTEC","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE M876-4 (EU) (6GK5876-4AA00-2BA2) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SIPROTEC 5 6MD89 (CP300) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-40808","product":{"name":"SIPROTEC","vendor":{"name":"Siemens","scada":true}}},{"description":"SIPROTEC 5 7SD87 (CP300) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-40808","product":{"name":"SIPROTEC","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE X206-1 (6GK5206-1BB10-2AA3) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SIMATIC WinCC Unified PC Runtime V19 toutes versions. L'\u00e9diteur indique que le produit ne b\u00e9n\u00e9ficiera pas de correctif de s\u00e9curit\u00e9 pour la vuln\u00e9rabilit\u00e9 CVE-2026-24349.","product":{"name":"SIMATIC","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE X308-2LH+ (6GK5308-2FP00-2AA3) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE XC324-4 EEC (6GK5328-4TS00-2EC2) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE X307-2 EEC (24V, coated) (6GK5307-2FD00-1GA3) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SIMATIC MV540 S (6GF3540-0CD10) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SIMATIC","vendor":{"name":"Siemens","scada":true}}},{"description":"SIMATIC IPC ORCLA toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SIMATIC","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE X310FE (6GK5310-0BA00-2AA3) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE X307-2 EEC (24V) (6GK5307-2FD00-1EA3) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE X307-2 EEC (2x 230V) (6GK5307-2FD00-4EA3) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SIMATIC IPC BX-21A toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SIMATIC","vendor":{"name":"Siemens","scada":true}}},{"description":"SIMATIC MV540 H (6GF3540-0GE10) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SIMATIC","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE X408-2 (6GK5408-2FD00-2AA2) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SIMATIC WinCC Unified PC Runtime V20 toutes versions. L'\u00e9diteur indique que le produit ne b\u00e9n\u00e9ficiera pas de correctif de s\u00e9curit\u00e9 pour la vuln\u00e9rabilit\u00e9 CVE-2026-24349.","product":{"name":"SIMATIC","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE M874-3 (6GK5874-3AA00-2AA2) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SIMATIC WinCC OA V3.21 versions ant\u00e9rieures \u00e0 3.21.02","product":{"name":"SIMATIC","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE XR324-4M EEC (2x 24V, ports on rear) (6GK5324-4GG10-2JR2) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE X308-2M TS (6GK5308-2GG10-2CA2) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE X302-7 EEC (230V) (6GK5302-7GD00-3EA3) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE X202-2P IRT PRO (6GK5202-2JR10-2BA6) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE XR502-32 (6GK5534-5TR00-4AR3) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE WUM763-1 (US) (6GK5763-1AL00-3DB0) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE X310FE (6GK5310-0BA10-2AA3) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE XR324-4M PoE (230V, ports on rear) (6GK5324-4QG00-3HR2) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SIPROTEC 5 7SA87 (CP300) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-40808","product":{"name":"SIPROTEC","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE MUB852-1 (B1) (6GK5852-1EA10-1BA1) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE X204-2 (6GK5204-2BB10-2AA3) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SIPROTEC 5 7SL87 (CP200) toutes versions. L'\u00e9diteur indique que le produit ne b\u00e9n\u00e9ficiera pas de correctif de s\u00e9curit\u00e9 pour la vuln\u00e9rabilit\u00e9 CVE-2025-40808.","product":{"name":"SIPROTEC","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE WUB762-1 iFeatures (6GK5762-1AJ00-2AA0) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE X308-2M TS (6GK5308-2GG00-2CA2) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE WUM766-1 (USA) (6GK5766-1GE00-3DB0) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE XR322-12 (6GK5334-3TS00-4AR3) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE XR522-12 (6GK5534-3TR00-4AR3) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE XR524-8WG (6GK5532-2SR00-3AR3) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SIMATIC MV530 H (6GF3530-0GE10) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SIMATIC","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE X204IRT (6GK5204-0BA10-2BA3) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SIMATIC RTLS Locating Manager (6GT2780-0DA30) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SIMATIC","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE M874-2 (6GK5874-2AA00-2AA2) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE X204RNA (HSR) (6GK5204-0BA00-2MB2) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SIMATIC WinCC Unified PC Runtime V21 versions ant\u00e9rieures \u00e0 21.0.2","product":{"name":"SIMATIC","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE XF206-1 (6GK5206-1BC00-2AF2) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE MUM853-1 (B1) (6GK5853-2EA10-2BA1) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE X307-2 EEC (230V) (6GK5307-2FD00-3EA3) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SIMATIC RTLS Locating Manager (6GT2780-0DA10) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SIMATIC","vendor":{"name":"Siemens","scada":true}}},{"description":"SIMATIC STEP 7 V5 versions ant\u00e9rieures \u00e0 5.7.4","product":{"name":"SIMATIC","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE X308-2M PoE (6GK5308-2QG00-2AA2) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SIPROTEC 5 7SL82 (CP100) toutes versions. L'\u00e9diteur indique que le produit ne b\u00e9n\u00e9ficiera pas de correctif de s\u00e9curit\u00e9 pour la vuln\u00e9rabilit\u00e9 CVE-2025-40808.","product":{"name":"SIPROTEC","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE MUM853-1 (A1) (6GK5853-2EA10-2AA1) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE X307-2 EEC (2x 230V, coated) (6GK5307-2FD00-4GA3) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SIPROTEC 5 7SD86 (CP200) toutes versions. L'\u00e9diteur indique que le produit ne b\u00e9n\u00e9ficiera pas de correctif de s\u00e9curit\u00e9 pour la vuln\u00e9rabilit\u00e9 CVE-2025-40808.","product":{"name":"SIPROTEC","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE SC632-2C (6GK5632-2GS00-2AC2) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front) (6GK5324-4GG00-4ER2) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SIPROTEC 5 7VE85 (CP300) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-40808","product":{"name":"SIPROTEC","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE MUB852-1 (A1) (6GK5852-1EA10-1AA1) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SIPROTEC 5 7SA86 (CP200) toutes versions. L'\u00e9diteur indique que le produit ne b\u00e9n\u00e9ficiera pas de correctif de s\u00e9curit\u00e9 pour la vuln\u00e9rabilit\u00e9 CVE-2025-40808.","product":{"name":"SIPROTEC","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE XC324-4 (6GK5328-4TS00-2AC2) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SIPROTEC 5 7UM85 (CP300) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-40808","product":{"name":"SIPROTEC","vendor":{"name":"Siemens","scada":true}}},{"description":"SIPROTEC 5 7SJ82 (CP150) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-40808","product":{"name":"SIPROTEC","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE S615 LAN-Router (6GK5615-0AA00-2AA2) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE WAM766-1 (US) (6GK5766-1GE00-7DB0) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE X308-2LH (6GK5308-2FN00-2AA3) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE XR526-8 (6GK5534-2TR00-4AR3) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SIPROTEC 5 7VU85 (CP300) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-40808","product":{"name":"SIPROTEC","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE WUM763-1 (6GK5763-1AL00-3AA0) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE X200-4P IRT (6GK5200-4AH10-2BA3) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE WAB762-1 (6GK5762-1AJ00-6AA0) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SIMATIC IPC MD-57A toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SIMATIC","vendor":{"name":"Siemens","scada":true}}},{"description":"SIMATIC WinCC V8.0 toutes versions. L'\u00e9diteur indique que le produit ne b\u00e9n\u00e9ficiera pas de correctif de s\u00e9curit\u00e9 pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467.","product":{"name":"SIMATIC","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE XR324-4M EEC (2x 24V, ports on front) (6GK5324-4GG00-2ER2) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE X302-7 EEC (24V, coated) (6GK5302-7GD00-1GA3) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE X204-2TS (6GK5204-2BB10-2CA2) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SIPROTEC 5 7ST85 (CP300) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-40808","product":{"name":"SIPROTEC","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE XC316-8 (6GK5324-8TS00-2AC2) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE X201-3P IRT (6GK5201-3BH00-2BA3) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE M876-4 (6GK5876-4AA10-2BA2) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SIMATIC WinCC Unified Sequence versions ant\u00e9rieures \u00e0 21","product":{"name":"SIMATIC","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE XR302-32 (6GK5334-5TS00-4AR3) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE WAM766-1 EEC (ME) (6GK5766-1GE00-7TC0) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE XR326-8 (6GK5334-2TS00-3AR3) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SIMATIC RTLS Locating Manager (6GT2780-1EA20) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SIMATIC","vendor":{"name":"Siemens","scada":true}}},{"description":"SIPROTEC 5 7SJ82 (CP100) toutes versions. L'\u00e9diteur indique que le produit ne b\u00e9n\u00e9ficiera pas de correctif de s\u00e9curit\u00e9 pour la vuln\u00e9rabilit\u00e9 CVE-2025-40808.","product":{"name":"SIPROTEC","vendor":{"name":"Siemens","scada":true}}},{"description":"SIMATIC MV560 X (6GF3560-0HE10) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SIMATIC","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE XR324-4M EEC (24V, ports on front) (6GK5324-4GG00-1ER2) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE XR302-32 (6GK5334-5TS00-2AR3) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE X204IRT (6GK5204-0BA00-2BA3) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE WUB762-1 (6GK5762-1AJ00-1AA0) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE X308-2LH+ (6GK5308-2FP10-2AA3) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SIMATIC WinCC OA V3.20 versions ant\u00e9rieures \u00e0 3.20.012","product":{"name":"SIMATIC","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE XR526-8 (6GK5534-2TR00-2AR3) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE X302-7 EEC (2x 230V, coated) (6GK5302-7GD00-4GA3) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE SC622-2C (6GK5622-2GS00-2AC2) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE X307-3 (6GK5307-3BL00-2AA3) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SIPROTEC 5 7KE85 (CP200) toutes versions. L'\u00e9diteur indique que le produit ne b\u00e9n\u00e9ficiera pas de correctif de s\u00e9curit\u00e9 pour la vuln\u00e9rabilit\u00e9 CVE-2025-40808.","product":{"name":"SIPROTEC","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE M876-4 (NAM) (6GK5876-4AA00-2DA2) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SIPROTEC 5 7SJ81 (CP150) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-40808","product":{"name":"SIPROTEC","vendor":{"name":"Siemens","scada":true}}},{"description":"SIPROTEC 5 7SD87 (CP200) toutes versions. L'\u00e9diteur indique que le produit ne b\u00e9n\u00e9ficiera pas de correctif de s\u00e9curit\u00e9 pour la vuln\u00e9rabilit\u00e9 CVE-2025-40808.","product":{"name":"SIPROTEC","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE WAM766-1 (6GK5766-1GE00-7DA0) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE X307-2 EEC (2x 24V) (6GK5307-2FD00-2EA3) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE XR522-12 (6GK5534-3TR00-2AR3) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE WUM763-1 (6GK5763-1AL00-3DA0) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SIPROTEC 5 7SY82 (CP150) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-40808","product":{"name":"SIPROTEC","vendor":{"name":"Siemens","scada":true}}},{"description":"SIPROTEC 5 7SK82 (CP100) toutes versions. L'\u00e9diteur indique que le produit ne b\u00e9n\u00e9ficiera pas de correctif de s\u00e9curit\u00e9 pour la vuln\u00e9rabilit\u00e9 CVE-2025-40808.","product":{"name":"SIPROTEC","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE XF201-3P IRT (6GK5201-3BH00-2BD2) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SIPROTEC 5 7UT87 (CP200) toutes versions. L'\u00e9diteur indique que le produit ne b\u00e9n\u00e9ficiera pas de correctif de s\u00e9curit\u00e9 pour la vuln\u00e9rabilit\u00e9 CVE-2025-40808.","product":{"name":"SIPROTEC","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE X306-1LD FE (6GK5306-1BF00-2AA3) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE X302-7 EEC (2x 24V) (6GK5302-7GD00-2EA3) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE XF204 (6GK5204-0BA00-2AF2) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE X204IRT PRO (6GK5204-0JA00-2BA6) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE X308-2 (6GK5308-2FL00-2AA3) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SIPROTEC 5 6MD84 (CP300) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-40808","product":{"name":"SIPROTEC","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE X204RNA EEC (HSR) (6GK5204-0BS00-2NA3) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SIPROTEC 5 7SK85 (CP200) toutes versions. L'\u00e9diteur indique que le produit ne b\u00e9n\u00e9ficiera pas de correctif de s\u00e9curit\u00e9 pour la vuln\u00e9rabilit\u00e9 CVE-2025-40808.","product":{"name":"SIPROTEC","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE XR324-4M PoE TS (24V, ports on front) (6GK5324-4QG00-1CR2) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE X202-2IRT (6GK5202-2BB00-2BA3) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE X212-2LD (6GK5212-2BC00-2AA3) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE MUM856-1 (B1) (6GK5856-2EA10-3BA1) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE M816-1 ADSL-Router family toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SIPROTEC 5 7UT87 (CP300) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-40808","product":{"name":"SIPROTEC","vendor":{"name":"Siemens","scada":true}}},{"description":"SIPROTEC 5 6MD86 (CP300) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-40808","product":{"name":"SIPROTEC","vendor":{"name":"Siemens","scada":true}}},{"description":"SIMATIC MV540 H CRANES (6GF3540-0GE30) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SIMATIC","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE XR324-12M (24V, ports on front) (6GK5324-0GG10-1AR2) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SIPROTEC 5 7SL82 (CP150) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-40808","product":{"name":"SIPROTEC","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE MUM856-1 (CN) (6GK5856-2EA00-3FA1) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE XR324-4M PoE TS (24V, ports on front) (6GK5324-4QG10-1CR2) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE XR324-12M TS (24V) (6GK5324-0GG00-1CR2) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SIPROTEC 5 7SL86 (CP200) toutes versions. L'\u00e9diteur indique que le produit ne b\u00e9n\u00e9ficiera pas de correctif de s\u00e9curit\u00e9 pour la vuln\u00e9rabilit\u00e9 CVE-2025-40808.","product":{"name":"SIPROTEC","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE X202-2P IRT (6GK5202-2BH10-2BA3) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE XR324-12M (24V, ports on rear) (6GK5324-0GG00-1HR2) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE X308-2LH (6GK5308-2FN10-2AA3) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE XR324-4M EEC (24V, ports on rear) (6GK5324-4GG10-1JR2) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear) (6GK5324-4GG00-4JR2) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SIMATIC WinCC OA V3.19 versions ant\u00e9rieures \u00e0 3.19.024","product":{"name":"SIMATIC","vendor":{"name":"Siemens","scada":true}}},{"description":"SIPROTEC 5 7SL86 (CP300) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-40808","product":{"name":"SIPROTEC","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE X201-3P IRT (6GK5201-3BH10-2BA3) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE XR322-12 (6GK5334-3TS00-2AR3) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SIPROTEC 5 6MD85 (CP200) toutes versions. L'\u00e9diteur indique que le produit ne b\u00e9n\u00e9ficiera pas de correctif de s\u00e9curit\u00e9 pour la vuln\u00e9rabilit\u00e9 CVE-2025-40808.","product":{"name":"SIPROTEC","vendor":{"name":"Siemens","scada":true}}},{"description":"SIMATIC MV560 U (6GF3560-0LE10) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SIMATIC","vendor":{"name":"Siemens","scada":true}}},{"description":"SIPROTEC 5 7SA82 (CP150) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-40808","product":{"name":"SIPROTEC","vendor":{"name":"Siemens","scada":true}}},{"description":"SIMATIC WinCC Unified PC Runtime V16 toutes versions. L'\u00e9diteur indique que le produit ne b\u00e9n\u00e9ficiera pas de correctif de s\u00e9curit\u00e9 pour la vuln\u00e9rabilit\u00e9 CVE-2026-24349.","product":{"name":"SIMATIC","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE M812-1 ADSL-Router family toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SIPROTEC 5 7VK87 (CP300) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-40808","product":{"name":"SIPROTEC","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE X204-2LD TS (6GK5204-2BC10-2CA2) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SIPROTEC 5 Compact 7SX800 (CP050) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-40808","product":{"name":"SIPROTEC","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE XR324-4M PoE (24V, ports on rear) (6GK5324-4QG00-1HR2) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE XF204-2 (6GK5204-2BC00-2AF2) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SIPROTEC 5 7UT82 (CP100) toutes versions. L'\u00e9diteur indique que le produit ne b\u00e9n\u00e9ficiera pas de correctif de s\u00e9curit\u00e9 pour la vuln\u00e9rabilit\u00e9 CVE-2025-40808.","product":{"name":"SIPROTEC","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE XR324-4M PoE (24V, ports on rear) (6GK5324-4QG10-1HR2) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE X308-2M PoE (6GK5308-2QG10-2AA2) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SIMATIC WinCC V7.5 toutes versions. L'\u00e9diteur indique que le produit ne b\u00e9n\u00e9ficiera pas de correctif de s\u00e9curit\u00e9 pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467.","product":{"name":"SIMATIC","vendor":{"name":"Siemens","scada":true}}},{"description":"SIMATIC RTLS Locating Manager (6GT2780-0DA00) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SIMATIC","vendor":{"name":"Siemens","scada":true}}},{"description":"SIMATIC IOT2050 (6ES7647-0BA00-1YA2) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SIMATIC","vendor":{"name":"Siemens","scada":true}}},{"description":"SIPROTEC 5 7UT82 (CP150) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-40808","product":{"name":"SIPROTEC","vendor":{"name":"Siemens","scada":true}}},{"description":"SIPROTEC 5 7ST85 (CP200) toutes versions. L'\u00e9diteur indique que le produit ne b\u00e9n\u00e9ficiera pas de correctif de s\u00e9curit\u00e9 pour la vuln\u00e9rabilit\u00e9 CVE-2025-40808.","product":{"name":"SIPROTEC","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE X307-3 (6GK5307-3BL10-2AA3) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE XR524-8WG (6GK5532-2SR00-2RR3) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE WUM766-1 (6GK5766-1GE00-3DA0) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE MUM856-1 (EU) (6GK5856-2EA00-3DA1) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE XR326-8 EEC (6GK5334-2TS00-2ER3) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SIMATIC PDM V9.3 toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SIMATIC","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE M876-3 (6GK5876-3AA02-2BA2) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SIMATIC MV550 H (6GF3550-0GE10) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SIMATIC","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE X320-1 FE (6GK5320-1BD00-2AA3) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE XF204IRT (6GK5204-0BA10-2BF2) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE XR524-8WG (6GK5532-2SR00-3RR3) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SIMATIC RTLS Locating Manager (6GT2780-0DA20) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SIMATIC","vendor":{"name":"Siemens","scada":true}}},{"description":"SIPROTEC 5 7VK87 (CP200) toutes versions. L'\u00e9diteur indique que le produit ne b\u00e9n\u00e9ficiera pas de correctif de s\u00e9curit\u00e9 pour la vuln\u00e9rabilit\u00e9 CVE-2025-40808.","product":{"name":"SIPROTEC","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE X212-2 (6GK5212-2BB00-2AA3) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SIMATIC Target toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SIMATIC","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front) (6GK5324-4GG00-3ER2) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE XF208 (6GK5208-0BA00-2AF2) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE XR324-12M (24V, ports on rear) (6GK5324-0GG10-1HR2) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE X302-7 EEC (2x 24V, coated) (6GK5302-7GD00-2GA3) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE WAM763-1 (6GK5763-1AL00-7DA0) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SIMATIC MV550 S (6GF3550-0CD10) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SIMATIC","vendor":{"name":"Siemens","scada":true}}},{"description":"SIMATIC HMI Mobile Panels versions ant\u00e9rieures \u00e0 17.0.9","product":{"name":"SIMATIC","vendor":{"name":"Siemens","scada":true}}},{"description":"SIPROTEC 5 7UT85 (CP300) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-40808","product":{"name":"SIPROTEC","vendor":{"name":"Siemens","scada":true}}},{"description":"SIMATIC RTLS Locating Manager (6GT2780-1EA10) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SIMATIC","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear) (6GK5324-4GG10-4JR2) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE X201-3P IRT PRO (6GK5201-3JR00-2BA6) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SIPROTEC 5 6MD85 (CP300) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-40808","product":{"name":"SIPROTEC","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE XR324-4M EEC (2x 24V, ports on front) (6GK5324-4GG10-2ER2) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SIPROTEC 5 7SJ81 (CP100) toutes versions. L'\u00e9diteur indique que le produit ne b\u00e9n\u00e9ficiera pas de correctif de s\u00e9curit\u00e9 pour la vuln\u00e9rabilit\u00e9 CVE-2025-40808.","product":{"name":"SIPROTEC","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE XR324-4M PoE (24V, ports on front) (6GK5324-4QG00-1AR2) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SIPROTEC 5 7UT86 (CP300) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-40808","product":{"name":"SIPROTEC","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE XC332 (6GK5332-0GA00-2AC2) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE SC642-2C (6GK5642-2GS00-2AC2) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE WAM763-1 (ME) (6GK5763-1AL00-7DC0) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE XR324-12M (230V, ports on front) (6GK5324-0GG00-3AR2) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE WAM766-1 EEC (US) (6GK5766-1GE00-7TB0) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE SC626-2C (6GK5626-2GS00-2AC2) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE X204RNA EEC (PRP/HSR) (6GK5204-0BS00-3PA3) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front) (6GK5324-4GG10-4ER2) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE LPE9413 (6GK5998-3GS01-2AC2) toutes versions. L'\u00e9diteur indique que le produit ne b\u00e9n\u00e9ficiera pas de correctif de s\u00e9curit\u00e9 pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467.","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE X202-2P IRT (6GK5202-2BH00-2BA3) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SIPROTEC 5 7SA87 (CP200) toutes versions. L'\u00e9diteur indique que le produit ne b\u00e9n\u00e9ficiera pas de correctif de s\u00e9curit\u00e9 pour la vuln\u00e9rabilit\u00e9 CVE-2025-40808.","product":{"name":"SIPROTEC","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE X224 (6GK5224-0BA00-2AA3) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SIPROTEC 5 7ST86 (CP300) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-40808","product":{"name":"SIPROTEC","vendor":{"name":"Siemens","scada":true}}},{"description":"SIMATIC HMI Basic Panels versions ant\u00e9rieures \u00e0 17.0.9","product":{"name":"SIMATIC","vendor":{"name":"Siemens","scada":true}}},{"description":"SIPROTEC 5 7SD86 (CP300) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-40808","product":{"name":"SIPROTEC","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE XC416-8 (6GK5424-8TR00-2AC2) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SIPROTEC 5 7SK82 (CP150) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-40808","product":{"name":"SIPROTEC","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE XR324-12M (24V, ports on front) (6GK5324-0GG00-1AR2) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE X308-2LD (6GK5308-2FM00-2AA3) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SIMATIC eaSie PCS 7 Skill Package (6DL5424-0BX00-0AV8) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SIMATIC","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE XR324-4M EEC (2x 24V, ports on rear) (6GK5324-4GG00-2JR2) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE WUM766-1 (ME) (6GK5766-1GE00-3DC0) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SIPROTEC 5 7UT85 (CP200) toutes versions. L'\u00e9diteur indique que le produit ne b\u00e9n\u00e9ficiera pas de correctif de s\u00e9curit\u00e9 pour la vuln\u00e9rabilit\u00e9 CVE-2025-40808.","product":{"name":"SIPROTEC","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE X307-2 EEC (230V, coated) (6GK5307-2FD00-3GA3) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SIPROTEC 5 7SD82 (CP100) toutes versions. L'\u00e9diteur indique que le produit ne b\u00e9n\u00e9ficiera pas de correctif de s\u00e9curit\u00e9 pour la vuln\u00e9rabilit\u00e9 CVE-2025-40808.","product":{"name":"SIPROTEC","vendor":{"name":"Siemens","scada":true}}},{"description":"SIPLUS NET SCALANCE X308-2 (6AG1308-2FL10-4AA3) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SIPLUS","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE XF204-2BA IRT (6GK5204-2AA00-2BD2) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE XR302-32 (6GK5334-5TS00-3AR3) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE X320-1-2LD FE (6GK5320-3BF00-2AA3) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SIPROTEC 5 7SA86 (CP300) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-40808","product":{"name":"SIPROTEC","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE XR324-4M EEC (24V, ports on front) (6GK5324-4GG10-1ER2) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE XR524-8WG (6GK5532-2SR00-2AR3) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SIPROTEC 5 7SD82 (CP150) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-40808","product":{"name":"SIPROTEC","vendor":{"name":"Siemens","scada":true}}},{"description":"SIPROTEC 5 7SX82 (CP150) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-40808","product":{"name":"SIPROTEC","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE XR502-32 (6GK5534-5TR00-3AR3) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE XF204IRT (6GK5204-0BA00-2BF2) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SIPROTEC 5 7SS85 (CP300) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-40808","product":{"name":"SIPROTEC","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE LPE9433 (6GK5998-3GS11-2AC2) toutes versions. L'\u00e9diteur indique que le produit ne b\u00e9n\u00e9ficiera pas de correctif de s\u00e9curit\u00e9 pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467.","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SIMATIC eaSie Core Package (6DL5424-0AX00-0AV8) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SIMATIC","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE XR324-4M PoE (24V, ports on front) (6GK5324-4QG10-1AR2) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SIMATIC WinCC V8.1 toutes versions. L'\u00e9diteur indique que le produit ne b\u00e9n\u00e9ficiera pas de correctif de s\u00e9curit\u00e9 pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467.","product":{"name":"SIMATIC","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE X201-3P IRT PRO (6GK5201-3JR10-2BA6) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE X308-2M (6GK5308-2GG10-2AA2) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE XR502-32 (6GK5534-5TR00-2AR3) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE X204IRT PRO (6GK5204-0JA10-2BA6) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE WAM763-1 (US) (6GK5763-1AL00-7DB0) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE X202-2IRT (6GK5202-2BB10-2BA3) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE X308-2 (6GK5308-2FL10-2AA3) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}},{"description":"SIPROTEC 5 7SJ86 (CP300) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-40808","product":{"name":"SIPROTEC","vendor":{"name":"Siemens","scada":true}}},{"description":"SCALANCE SC636-2C (6GK5636-2GS00-2AC2) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-15467","product":{"name":"SCALANCE","vendor":{"name":"Siemens","scada":true}}}],"affected_systems_content":"","content":"## Solutions\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l'\u00e9diteur pour l'obtention des correctifs (cf. section Documentation).","cves":[{"name":"CVE-2025-15467","url":"https://www.cve.org/CVERecord?id=CVE-2025-15467"},{"name":"CVE-2026-24349","url":"https://www.cve.org/CVERecord?id=CVE-2026-24349"},{"name":"CVE-2025-40808","url":"https://www.cve.org/CVERecord?id=CVE-2025-40808"}],"links":[],"reference":"CERTFR-2026-AVI-0714","revisions":[{"description":"Version initiale","revision_date":"2026-06-09T00:00:00.000000"}],"risks":[{"description":"D\u00e9ni de service \u00e0 distance"},{"description":"Ex\u00e9cution de code arbitraire \u00e0 distance"},{"description":"Atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es"}],"summary":"De multiples vuln\u00e9rabilit\u00e9s ont \u00e9t\u00e9 d\u00e9couvertes dans les produits Siemens. Elles permettent \u00e0 un attaquant de provoquer une ex\u00e9cution de code arbitraire \u00e0 distance, un d\u00e9ni de service \u00e0 distance et une atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es.","title":"Multiples vuln\u00e9rabilit\u00e9s dans les produits Siemens","vendor_advisories":[{"published_at":"2026-06-09","title":"Bulletin de s\u00e9curit\u00e9 Siemens SSA-139483","url":"https://cert-portal.siemens.com/productcert/html/ssa-139483.html"},{"published_at":"2026-06-09","title":"Bulletin de s\u00e9curit\u00e9 Siemens SSA-063511","url":"https://cert-portal.siemens.com/productcert/html/ssa-063511.html"},{"published_at":"2026-06-09","title":"Bulletin de s\u00e9curit\u00e9 Siemens SSA-434797","url":"https://cert-portal.siemens.com/productcert/html/ssa-434797.html"}]}